US_HISCO_SPIRE
Fluke Networks

Certifiber Pro Quad OLTS V2, with Double Ended Inspection

Hisco #:CFP2-100-QI-NW-65681

MFG #:CFP2-100-QI-NW

Our Price: $20,534.99 PC
Manufacturer Lead Time When Not In Stock14 days
Minimum Order QTY: 1
Item must be ordered in multiples of 1

The Fluke Networks CFP2-100-QI-NW is a CertiFiber® Pro Optical Loss Test Set with Quad OLTS, double-ended inspection for Tier 1 (basic) and OTDR Tier 2 (extended) fiber certifications.

Fluke Networks CFP2-100-QI-NW Features:
  • Simplifies set-up
  • Eliminates errors
  • Speeds up troubleshooting
  • Ensures correct reference settings and eliminates negative loss errors via set reference wizard
  • Double ended Pass/Fail certification
  • Certify fiber optic endfaces to industry standards: IEC 61300-3-35
  • Made in the USA
Fluke Networks CFP2-100-QI-NW Specifications:
  • Brand: Fluke Networks
  • Dimensions: 17" x 16" x 12"
  • Input Connector:Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Detector Type: InGaAs
  • Wavelengths: 850 nm, 1300 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty: < +/- 5% +/- 32 pW
  • Measurement Linearity: < ± 0.1 dB
  • Re-calibration Period: 1 year
  • Input/Output Connectors:Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Launch Condition: Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
  • Fiber Types Tested: 50/125 µm or 62.5/125 µm
  • Source Type and Wavelengths: LED source 850 nm ± 30 nm 1300 nm ± 20 nm
  • Maximum Length Measurement: 12 km
  • Length Measurement Accuracy: ± 1.5 m plus ± 1 % of length
  • Output Power (Nominal): ≥ -24 dBm with EF-TRC
  • Output Power Stability: ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes
  • Source Wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty: < +/- 5% +/- 32 pW
  • Measurement Linearity: < ± 0.1 dB
  • Operating Temperature: -18° C to 45° C
  • Storage Temperature: -30° C to +60° C
  • Operating Relative Humidity: % RH without condensation 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C); 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
  • Vibration: Random, 2 g, 5 Hz-500 Hz
  • Shock: 1 m drop test with and without module and adapters
  • Safety: CSA C22.2 No. 1010.1: 1992; EN 61010-1 1st Edition + Amendments 1, 2
  • Pollution Degree: 2
  • Altitude: Operating: 4,000 m; storage: 12,000 m
  • EMC: EN 61326–1
  • Fiber Test Methods: OLTS
  • Fiber Type: Multi mode
  • Copper Testing: No

Product Description

The Fluke Networks CFP2-100-QI-NW is a CertiFiber® Pro Optical Loss Test Set with Quad OLTS, double-ended inspection for Tier 1 (basic) and OTDR Tier 2 (extended) fiber certifications.

Fluke Networks CFP2-100-QI-NW Features:
  • Simplifies set-up
  • Eliminates errors
  • Speeds up troubleshooting
  • Ensures correct reference settings and eliminates negative loss errors via set reference wizard
  • Double ended Pass/Fail certification
  • Certify fiber optic endfaces to industry standards: IEC 61300-3-35
  • Made in the USA
Fluke Networks CFP2-100-QI-NW Specifications:
  • Brand: Fluke Networks
  • Dimensions: 17" x 16" x 12"
  • Input Connector:Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Detector Type: InGaAs
  • Wavelengths: 850 nm, 1300 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty: < +/- 5% +/- 32 pW
  • Measurement Linearity: < ± 0.1 dB
  • Re-calibration Period: 1 year
  • Input/Output Connectors:Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Launch Condition: Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
  • Fiber Types Tested: 50/125 µm or 62.5/125 µm
  • Source Type and Wavelengths: LED source 850 nm ± 30 nm 1300 nm ± 20 nm
  • Maximum Length Measurement: 12 km
  • Length Measurement Accuracy: ± 1.5 m plus ± 1 % of length
  • Output Power (Nominal): ≥ -24 dBm with EF-TRC
  • Output Power Stability: ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes
  • Source Wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty: < +/- 5% +/- 32 pW
  • Measurement Linearity: < ± 0.1 dB
  • Operating Temperature: -18° C to 45° C
  • Storage Temperature: -30° C to +60° C
  • Operating Relative Humidity: % RH without condensation 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C); 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
  • Vibration: Random, 2 g, 5 Hz-500 Hz
  • Shock: 1 m drop test with and without module and adapters
  • Safety: CSA C22.2 No. 1010.1: 1992; EN 61010-1 1st Edition + Amendments 1, 2
  • Pollution Degree: 2
  • Altitude: Operating: 4,000 m; storage: 12,000 m
  • EMC: EN 61326–1
  • Fiber Test Methods: OLTS
  • Fiber Type: Multi mode
  • Copper Testing: No

Technical Information

BrandFluke Networks
Weight: 7.936

Additional Resources

Our Price: $20,534.99 PC
 
Minimum Order QTY: 1
Item must be ordered in multiples of 1
North America's Premier Distributor of Mission Critical Materials © 2008-  Copyright Hisco – TestEquity LLC.  All rights reserved.