US_HISCO_SPIRE
Information notification:
Due to ongoing tariff updates, pricing is subject to change and may not reflect the latest surcharges.
Fluke logo

Small-Diameter Industrial RTD with Mini Spade Lugs, 12in

Hisco #:3003291-19816

MFG #:3003291

$
Manufacturer Lead Time When Not In Stock14 days
Minimum Order QTY: 1
Item must be ordered in multiples of 1

The Fluke 3003291 5618B-12-L sheath helps reduce response time while maintaining high accuracy. The RTD has full ITS-90 calibration, a 12" (304.8 mm) length, and mini spade lug connections.

Fluke 3003291 Features:
  • Excellent stability
  • Includes ITS-90 coefficients
  • NVLAP-accredited calibration from -328 to 932°F (-200 to 500°C), lab code 200706-0
Fluke 3003291 Specifications:
  • Brand: Fluke
  • Product Type: Probes
  • Resistance: Nominal 100 Ω at 32°F (0°C)
  • Temperature Coefficient: 0.003923 Ω/Ω/°C nominal
  • Temperature Range: -328 to 932°F (-200 to 500°C)
  • Drift Rate: ±0.1°C when used periodically to 932°F (500°C)
  • Sheath Material: 316 SST
  • Leads: 22 AWG Teflon, 6' (152.4 mm)
  • Termination: Specify
  • Hysteresis: Less than 0.01°C at 0°C when using –196°C and 420°C as the end points
  • Time Constant: 9 seconds max for 63.2%
  • Thermal EMF: Less than 25 mV at 420°C
  • Calibration: Includes manufacturer's NVLAP-accredited calibration w/ITS-90 coefficients, R vs. T values in 1°C increments, lab code 200706-0
  • Probe Accuracy: ±0.05°C over entire range
  • Dimensions: 12 x 1⁄8" (305 x 3.2 mm)

Product Description

The Fluke 3003291 5618B-12-L sheath helps reduce response time while maintaining high accuracy. The RTD has full ITS-90 calibration, a 12" (304.8 mm) length, and mini spade lug connections.

Fluke 3003291 Features:
  • Excellent stability
  • Includes ITS-90 coefficients
  • NVLAP-accredited calibration from -328 to 932°F (-200 to 500°C), lab code 200706-0
Fluke 3003291 Specifications:
  • Brand: Fluke
  • Product Type: Probes
  • Resistance: Nominal 100 Ω at 32°F (0°C)
  • Temperature Coefficient: 0.003923 Ω/Ω/°C nominal
  • Temperature Range: -328 to 932°F (-200 to 500°C)
  • Drift Rate: ±0.1°C when used periodically to 932°F (500°C)
  • Sheath Material: 316 SST
  • Leads: 22 AWG Teflon, 6' (152.4 mm)
  • Termination: Specify
  • Hysteresis: Less than 0.01°C at 0°C when using –196°C and 420°C as the end points
  • Time Constant: 9 seconds max for 63.2%
  • Thermal EMF: Less than 25 mV at 420°C
  • Calibration: Includes manufacturer's NVLAP-accredited calibration w/ITS-90 coefficients, R vs. T values in 1°C increments, lab code 200706-0
  • Probe Accuracy: ±0.05°C over entire range
  • Dimensions: 12 x 1⁄8" (305 x 3.2 mm)

Technical Information

BrandFluke
$
 
Minimum Order QTY: 1
Item must be ordered in multiples of 1
North America's Premier Distributor of Mission Critical Materials © 2008-  Copyright Hisco – TestEquity LLC.  All rights reserved.