The Fluke 3054148 has a built-in two channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20mA transmitters which includes the 24V loop supply to power the transmitter.

Fluke 3054148 Features:
  • Each process version provides built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24V loop supply to power the transmitter
  • Accuracy ranges from ±0.01°C to ±0.07°C depending on the measured temperature
  • Accepts an ITS-90 reference PRT that contains individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably
  • Second channel is user-selectable for 2-, 3-, or 4-wire RTDs, thermo-couples, or 4-20 mA transmitters
  • With 24V loop power and measure the trans-mitter current while sourcing and measuring temperature thus allowing for the measurement of as-found and as-left data in one self-contained calibration tool
Fluke 3054148 Specifications:
  • Brand: Fluke
  • Product Type: Current Calibrators
  • Ref. Characterizations: 4-wire, ITS-90, CVD, IEC-751, Resistance
  • Ref. Resistance Range: 0 to 400Ω
  • Ref. Resistance Accuracy: 0-25Ω: ±0.002Ω, 25-400Ω: ±60 ppm
  • RTD Characterizations: 4-wire RTD (2-, 3-wire RTD w/ jumpers only), PT-100 (385), (JIS), (3926), Ni-12, Resistance
  • RTD Therm. Accuracy: Ni-120: ±0.1°C @ 0°C; Pt-100 (385): ±0.02°C @ 0°C; Pt-100 (3926): ±0.02°C @ 0°C;Pt-100 (JIS): ±0.02°C @ 0°C
  • RTD Resistance Range: 0 to 400Ω
  • RTD Resistance Accuracy 0-25Ω: ±0.002Ω, 25-400Ω: ±80 ppm

Product Description

The Fluke 3054148 has a built-in two channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20mA transmitters which includes the 24V loop supply to power the transmitter.

Fluke 3054148 Features:
  • Each process version provides built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24V loop supply to power the transmitter
  • Accuracy ranges from ±0.01°C to ±0.07°C depending on the measured temperature
  • Accepts an ITS-90 reference PRT that contains individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably
  • Second channel is user-selectable for 2-, 3-, or 4-wire RTDs, thermo-couples, or 4-20 mA transmitters
  • With 24V loop power and measure the trans-mitter current while sourcing and measuring temperature thus allowing for the measurement of as-found and as-left data in one self-contained calibration tool
Fluke 3054148 Specifications:
  • Brand: Fluke
  • Product Type: Current Calibrators
  • Ref. Characterizations: 4-wire, ITS-90, CVD, IEC-751, Resistance
  • Ref. Resistance Range: 0 to 400Ω
  • Ref. Resistance Accuracy: 0-25Ω: ±0.002Ω, 25-400Ω: ±60 ppm
  • RTD Characterizations: 4-wire RTD (2-, 3-wire RTD w/ jumpers only), PT-100 (385), (JIS), (3926), Ni-12, Resistance
  • RTD Therm. Accuracy: Ni-120: ±0.1°C @ 0°C; Pt-100 (385): ±0.02°C @ 0°C; Pt-100 (3926): ±0.02°C @ 0°C;Pt-100 (JIS): ±0.02°C @ 0°C
  • RTD Resistance Range: 0 to 400Ω
  • RTD Resistance Accuracy 0-25Ω: ±0.002Ω, 25-400Ω: ±80 ppm