US_HISCO_SPIRE
Information notification:
Due to ongoing tariff updates, pricing is subject to change and may not reflect the latest surcharges.
Fluke Networks

2GHZ DSX Cable Analyzer with Quad OTDR, Quad OLTS, Fiber Inspection, Wi-fi

Hisco #:DSX2-8000QOI-65681

MFG #:DSX2-8000QOI

$
Manufacturer Lead Time When Not In Stock14 days
Minimum Order QTY: 1
Item must be ordered in multiples of 1

The Fluke Networks DSX2-8000QOI is a DSX2-8000 Cable Analyzer with Quad OTDR, Quad OLTS, Fiber Inspection and Wi-Fi.

Fluke Networks DSX2-8000QOI Features:
  • Supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  • Graphically displays the source of failures
  • Simplifies set-up, and eliminates errors
  • Analyze test results and create professional test reports using LinkWare management software
  • Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
  • Made in the USA
Fluke Networks DSX2-8000QOI Specifications:
  • Brand: Fluke Networks
  • Category 8 test modes (or lower link categories): ANSI/TIA-1152 Level 2G
  • Class I/II test modes: Proposed standard IEC 61935-1 Ed. 5 Level VI
  • Range: 800 m (2600 ft); With Remote: 150 m (490 ft)
  • Resolution: 0.1 m or 1 ft; With Remote: 0.1 m or 1 ft
  • Accuracy: ± (0.3 m + 2 %); 0 m to 150 m; ± (0.3 m + 4 %); 150 m to 800 m; With Remote: ± (0.3 m + 2 %)
  • Propagation Delay Range: 4000 ns; With Remote: 750 ns
  • Propagation Delay Resolution: 1 ns
  • Propagation Delay Accuracy: ± (2 ns + 2 %); 0 ns to 750 ns; ± (2 ns + 4 %); 750 ns to 4000 ns; With Remote: ± (2 ns + 2 %)
  • Delay Skew Range: 0 ns to 100 ns
  • Delay Skew Resolution: 1 ns
  • Delay Skew Accuracy: ± 10 ns
  • Input Connector: Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Detector Type: InGaAs
  • Wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty: < +/- 5% +/- 32 pW
  • Measurement Linearity: < ± 0.1 dB
  • Re-calibration Period: 1 year
  • Output Power: >-5 dBm; <0 dBm; SMF-28 singlemode fiber; Continuous wave; SC/UPC connector
  • Operating Wavelength: 650 nm nominal
  • Output Modes: Continuous wave; Pulsed mode (2 Hz to 3 Hz blink frequency)
  • Connector Adapter: 2.5 mm universal
  • Laser Safety: Class II CDRH; Over operating temperature range
  • Operating Temperature: -18° C to 45° C
  • Storage Temperature: -30° C to +60° C
  • Operating Relative Humidity: 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
  • % RH without condensation: 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
  • Vibration: Random, 2 g, 5 Hz-500 Hz
  • Shock: 1 m drop test with and without module and adapters
  • Safety: CSA C22.2 No. 1010.1: 1992; EN 61010-1 1st Edition + Amendments 1, 2
  • Pollution Degree: 2
  • Altitude: Operating: 4,000 m; storage: 12,000 m
  • EMC: EN 61326–1
  • Kit Includes: Versiv Mainframe & Remote; (2) DSX-8000 CableAnalyzer™ modules; (2) CertiFiber Quad OLTS modules; OptiFiber Quad OTDR module; Set of Cat 8/Class I Permanent Link Adapters; Set of Cat 8/Class 1 Channel Adapters; (2) Headsets; (2) Hand Straps; (2) Shoulder Straps; Hard sided Carry Case; USB Interface Cable; Versiv Open Source Software CD; (2) AC Chargers; (2) Universal Couplers; (2) AxTalk Terminators; (2) Quick Clean Cleaners (1.25/2.50 mm); SC/SC Simplex adapters; 2 SC/LC Multimode Launch Cables—50 µm; 2 SC/LC Singlemode Launch Cable—9 µm; USB Fiber Inspection Video Probe with 4 Tips; (2) LC/LC Simplex Adapter; SC/LC EF-Compliant MM TRC Kit 50 µm; SC/LC SM TRC Kit; TRC Carry Case; Statement of Calibration; Getting Started Guides

Product Description

The Fluke Networks DSX2-8000QOI is a DSX2-8000 Cable Analyzer with Quad OTDR, Quad OLTS, Fiber Inspection and Wi-Fi.

Fluke Networks DSX2-8000QOI Features:
  • Supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  • Graphically displays the source of failures
  • Simplifies set-up, and eliminates errors
  • Analyze test results and create professional test reports using LinkWare management software
  • Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
  • Made in the USA
Fluke Networks DSX2-8000QOI Specifications:
  • Brand: Fluke Networks
  • Category 8 test modes (or lower link categories): ANSI/TIA-1152 Level 2G
  • Class I/II test modes: Proposed standard IEC 61935-1 Ed. 5 Level VI
  • Range: 800 m (2600 ft); With Remote: 150 m (490 ft)
  • Resolution: 0.1 m or 1 ft; With Remote: 0.1 m or 1 ft
  • Accuracy: ± (0.3 m + 2 %); 0 m to 150 m; ± (0.3 m + 4 %); 150 m to 800 m; With Remote: ± (0.3 m + 2 %)
  • Propagation Delay Range: 4000 ns; With Remote: 750 ns
  • Propagation Delay Resolution: 1 ns
  • Propagation Delay Accuracy: ± (2 ns + 2 %); 0 ns to 750 ns; ± (2 ns + 4 %); 750 ns to 4000 ns; With Remote: ± (2 ns + 2 %)
  • Delay Skew Range: 0 ns to 100 ns
  • Delay Skew Resolution: 1 ns
  • Delay Skew Accuracy: ± 10 ns
  • Input Connector: Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Detector Type: InGaAs
  • Wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty: < +/- 5% +/- 32 pW
  • Measurement Linearity: < ± 0.1 dB
  • Re-calibration Period: 1 year
  • Output Power: >-5 dBm; <0 dBm; SMF-28 singlemode fiber; Continuous wave; SC/UPC connector
  • Operating Wavelength: 650 nm nominal
  • Output Modes: Continuous wave; Pulsed mode (2 Hz to 3 Hz blink frequency)
  • Connector Adapter: 2.5 mm universal
  • Laser Safety: Class II CDRH; Over operating temperature range
  • Operating Temperature: -18° C to 45° C
  • Storage Temperature: -30° C to +60° C
  • Operating Relative Humidity: 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
  • % RH without condensation: 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
  • Vibration: Random, 2 g, 5 Hz-500 Hz
  • Shock: 1 m drop test with and without module and adapters
  • Safety: CSA C22.2 No. 1010.1: 1992; EN 61010-1 1st Edition + Amendments 1, 2
  • Pollution Degree: 2
  • Altitude: Operating: 4,000 m; storage: 12,000 m
  • EMC: EN 61326–1
  • Kit Includes: Versiv Mainframe & Remote; (2) DSX-8000 CableAnalyzer™ modules; (2) CertiFiber Quad OLTS modules; OptiFiber Quad OTDR module; Set of Cat 8/Class I Permanent Link Adapters; Set of Cat 8/Class 1 Channel Adapters; (2) Headsets; (2) Hand Straps; (2) Shoulder Straps; Hard sided Carry Case; USB Interface Cable; Versiv Open Source Software CD; (2) AC Chargers; (2) Universal Couplers; (2) AxTalk Terminators; (2) Quick Clean Cleaners (1.25/2.50 mm); SC/SC Simplex adapters; 2 SC/LC Multimode Launch Cables—50 µm; 2 SC/LC Singlemode Launch Cable—9 µm; USB Fiber Inspection Video Probe with 4 Tips; (2) LC/LC Simplex Adapter; SC/LC EF-Compliant MM TRC Kit 50 µm; SC/LC SM TRC Kit; TRC Carry Case; Statement of Calibration; Getting Started Guides

Technical Information

BrandFluke Networks
AvailabilityIn Stock
Weight: 0.936
UPC Code: 754082104599

Additional Resources

$
 
Minimum Order QTY: 1
Item must be ordered in multiples of 1
North America's Premier Distributor of Mission Critical Materials © 2008-  Copyright Hisco – TestEquity LLC.  All rights reserved.