US_HISCO_SPIRE

Save 10% when you spend $500+ on solder wire & bar. Code: SOLDER10. Online only. Ends 2/27.

Fluke Networks

CableAnalyzer Copper Certifier/Versiv 2 Kit with Quad OLTS, Quad OTDR, Fiber Inspection, and 1 Year

Hisco #:DSX2-8QOI-GLD-NW-65681

MFG #:DSX2-8QOI/GLD-NW

Our Price: $49,795.11 PC
List Price: 51088.49 PC
Available to Order - 0 on Hand
Manufacturer Estimated Lead Time When Not In Stock14 days
Minimum Order QTY: 1
Item must be ordered in multiples of 1

The Fluke Networks DSX2-8QOI/GLD-NW is a 2 GHz DSX2-8000 Cable Analyzer with Quad OTDR, Quad OLTS, Fiber Inspection and 1 Year of Gold Support, without Wi-Fi.

Fluke Networks DSX2-8QOI/GLD-NW Features:
  • Supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  • Graphically displays the source of failures
  • Simplifies set-up, and eliminates errors
  • Analyze test results and create professional test reports using LinkWare management software
  • Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
  • Made in the USA
  • Includes 1 year of Gold Support from Fluke Networks
Fluke Networks DSX2-8QOI/GLD-NW Specifications:
  • Brand: Fluke Networks
  • Kit Includes: Versiv Mainframe & Remote; (2) DSX-8000 CableAnalyzer™ modules; (2) CertiFiber Quad OLTS modules; OptiFiber Quad OTDR module; Set of Cat 8/Class I Permanent Link Adapters; Set of Cat 8/Class 1 Channel Adapters; (2) Headsets; (2) Hand Straps; (2) Shoulder Straps; Hard sided Carry Case; USB Interface Cable; Versiv Open Source Software CD; (2) AC Chargers; (2) Universal Couplers; (2) AxTalk Terminators; (2) Quick Clean Cleaners (1.25/2.50 mm); SC/SC Simplex adapters; 2 SC/LC Multimode Launch Cables—50 µm; 2 SC/LC Singlemode Launch Cable—9 µm; USB Fiber Inspection Video Probe with 4 Tips; (2) LC/LC Simplex Adapter; SC/LC EF-Compliant MM TRC Kit 50 µm; SC/LC SM TRC Kit; TRC Carry Case; Statement of Calibration; Getting Started Guides; 1 Year of Gold Support from Fluke Networks
  • Category 8 test modes (or lower link categories): ANSI/TIA-1152 Level 2G
  • Class I/II test modes: Proposed standard IEC 61935-1 Ed. 5 Level VI
  • Propagation Delay Range: 4000 ns; Without Remote: 750 ns
  • Propagation Delay Resolution: 1 ns; Without Remote: 1 ns
  • Propagation Delay Accuracy: ± (2 ns + 2 %); 0 ns to 750 ns; ± (2 ns + 4 %); 750 ns to 4000 ns; Without Remote: ± (2 ns + 2 %)
  • DC Loop Resistance Test Range: 0 Ω to 540 Ω
  • DC Loop Resistance Test Resolution: 0.1 Ω
  • DC Loop Resistance Test Accuracy: ± (1 Ω + 1 %)
  • DC Loop Resistance Test Overload recovery time: Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage
  • Input Connector: Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Detector Type: InGaAs
  • Input Connector: Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Detector Type: InGaAs
  • Wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty: < +/- 5% +/- 32 pW
  • Measurement Linearity: < ± 0.1 dB
  • Re-calibration Period: 1 year
  • Output Power: >-5 dBm; <0 dBm; SMF-28 singlemode fiber; Continuous wave; SC/UPC connector
  • Operating Wavelength: 650 nm nominal
  • Output Modes: Continuous wave; Pulsed mode (2 Hz to 3 Hz blink frequency)
  • Connector Adapter: 2.5 mm universal
  • Laser Safety: Class II CDRH; Over operating temperature range

Product Description

The Fluke Networks DSX2-8QOI/GLD-NW is a 2 GHz DSX2-8000 Cable Analyzer with Quad OTDR, Quad OLTS, Fiber Inspection and 1 Year of Gold Support, without Wi-Fi.

Fluke Networks DSX2-8QOI/GLD-NW Features:
  • Supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  • Graphically displays the source of failures
  • Simplifies set-up, and eliminates errors
  • Analyze test results and create professional test reports using LinkWare management software
  • Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
  • Made in the USA
  • Includes 1 year of Gold Support from Fluke Networks
Fluke Networks DSX2-8QOI/GLD-NW Specifications:
  • Brand: Fluke Networks
  • Kit Includes: Versiv Mainframe & Remote; (2) DSX-8000 CableAnalyzer™ modules; (2) CertiFiber Quad OLTS modules; OptiFiber Quad OTDR module; Set of Cat 8/Class I Permanent Link Adapters; Set of Cat 8/Class 1 Channel Adapters; (2) Headsets; (2) Hand Straps; (2) Shoulder Straps; Hard sided Carry Case; USB Interface Cable; Versiv Open Source Software CD; (2) AC Chargers; (2) Universal Couplers; (2) AxTalk Terminators; (2) Quick Clean Cleaners (1.25/2.50 mm); SC/SC Simplex adapters; 2 SC/LC Multimode Launch Cables—50 µm; 2 SC/LC Singlemode Launch Cable—9 µm; USB Fiber Inspection Video Probe with 4 Tips; (2) LC/LC Simplex Adapter; SC/LC EF-Compliant MM TRC Kit 50 µm; SC/LC SM TRC Kit; TRC Carry Case; Statement of Calibration; Getting Started Guides; 1 Year of Gold Support from Fluke Networks
  • Category 8 test modes (or lower link categories): ANSI/TIA-1152 Level 2G
  • Class I/II test modes: Proposed standard IEC 61935-1 Ed. 5 Level VI
  • Propagation Delay Range: 4000 ns; Without Remote: 750 ns
  • Propagation Delay Resolution: 1 ns; Without Remote: 1 ns
  • Propagation Delay Accuracy: ± (2 ns + 2 %); 0 ns to 750 ns; ± (2 ns + 4 %); 750 ns to 4000 ns; Without Remote: ± (2 ns + 2 %)
  • DC Loop Resistance Test Range: 0 Ω to 540 Ω
  • DC Loop Resistance Test Resolution: 0.1 Ω
  • DC Loop Resistance Test Accuracy: ± (1 Ω + 1 %)
  • DC Loop Resistance Test Overload recovery time: Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage
  • Input Connector: Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Detector Type: InGaAs
  • Input Connector: Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Detector Type: InGaAs
  • Wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty: < +/- 5% +/- 32 pW
  • Measurement Linearity: < ± 0.1 dB
  • Re-calibration Period: 1 year
  • Output Power: >-5 dBm; <0 dBm; SMF-28 singlemode fiber; Continuous wave; SC/UPC connector
  • Operating Wavelength: 650 nm nominal
  • Output Modes: Continuous wave; Pulsed mode (2 Hz to 3 Hz blink frequency)
  • Connector Adapter: 2.5 mm universal
  • Laser Safety: Class II CDRH; Over operating temperature range

Technical Information

BrandFluke Networks
Weight: 0.947
UPC Code: 754082137221
Our Price: $49,795.11 PC
List Price: 51088.49 PC
Available to Order - 0 on Hand
 
Minimum Order QTY: 1
Item must be ordered in multiples of 1
North America's Premier Distributor of Mission Critical Materials © 2008-  Copyright Hisco – TestEquity LLC.  All rights reserved.